Key takeaways
- Dew point is the temperature at which air starts to drop moisture.
- The slab should be at least 5 degrees F above the dew point.
- Check the slab, not just the air.
What dew point is
Dew point is the temperature at which the air can no longer hold its moisture and water starts to condense. On a humid morning a cold slab can sweat even when the air feels dry.
Why it matters
A thin film of condensation on the slab ruins the bond of a coating and can cause blushing, cloudiness or a sticky surface. Most coating makers want the slab at least five degrees Fahrenheit above the dew point during the application and the cure.
How to check
- Measure the air temperature and the humidity.
- Calculate the dew point from them.
- Measure the slab temperature with an infrared thermometer.
- Coat only when the slab is at least five degrees above the dew point.
Our Dew Point tool does the arithmetic and gives a go or no-go reading.
Related services
Questions about your own garage? Call or text (800) 207-0499, or use the quote form below.